A versatile mix for both end-point PCR genotyping and qPCR applications

DNA and RNA extracted from agricultural samples can be especially challenging for PCR and qPCR, and often require the use of robust master mixes and enzymes. BHQ™ (Black Hole Quencher™) Probe Master Mix delivers the performance needed to maximise PCR efficiency and data quality from agricultural samples regardless of the input quality.

BHQ Probe Master Mix is a 2X PCR mix containing a reliable hot start Taq DNA Polymerase designed to perform especially well with all BHQ-labelled hydrolysis probes and DNA templates from a variety of agriculture sample types in both singleplex and multiplex PCR applications.

Geared for high selectivity and low background, the BHQ Probe/BHQ Probe Master Mix combination delivers high-precision, unambiguous SNP genotyping, Copy Number Variation (CNV), and Adventitious Presence (AP) answers critical for advancing your trait development and commercialisation pipeline.

  • One robust and dependable master mix for both endpoint PCR and qPCR applications driving operational efficiency across all workflows.
  • Optimised for miniaturisation and scalable to a wide range of reaction volumes for different instrument platforms (1.6-25 µL).
  • Sensitive and dependable qPCR data with consistent high performance efficiency over a wide dynamic range, from 100,000 down to 10 target copies per reaction even at miniaturised reaction volumes.

Bulk/OEM available: Contact us about bulk orders, custom formulations, and dispensing options.

Filter product list:
Catalog # Item name Price Size/Scale Note Qty Add Conjugation ratio

${{item.salePrice}} ${{item.userPriceBook.salePrice}} ${{item.unitPrice}} ${{item.userPriceBook.unitPrice}} TBD {{item.sizeAndScale}} {{item.message}}

Copy Number Variation (CNV) Identification (qPCR)

Dependable quantification of wheat genome markers is achieved with BHQ Probe Master Mix and BHQnova assays

Figure 1: Accurate copy number variation (CNV) values were determined with BHQnova Probes and BHQ Probe Master Mix in a qPCR reaction. CNV was performed by utilising two published assays targeting (a) Ppd-B1 (photoperiod) and (b) Vrn-A1 (vernalisation), which are known to present CNV in the wheat genome. In both instances 2X BHQ Probe Master Mix was used either with FAM-labelled BHQnova or Competitor A probes (200 nM final concentration) in a 20 μL reaction volume, against a range of wheat varieties. Overall, BHQ Probe Master Mix, when used with BHQnova Probes presented more accurate CNV determination compared with Competitor A probes. Error bars represent standard deviation across replicates tested.

A guide to ROX levels and dye combinations for various instruments

ROX is a passive reference dye, which can aid with the normalisation of results. The process by which commercial qPCR instruments use ROX values for normalisation is dependent on the algorithms in their analysis software. LGC Biosearch Technologies have developed BHQ Probe Master Mix with different levels of ROX to account for these analysis differences.

Singleplex assays

The table below outlines the optimal ROX level of BHQ Probe Master Mix for the most commonly used qPCR instruments when running singleplex end-point genotyping assays or multiplex qPCR assays. For FRET-capable plate readers, Biosearch Technologies recommends initial trials with standard ROX BHQ Probe Master Mix.

If you are performing multiplex reactions, please scroll down to the next section.

Table 1: Recommended BHQ Probe Master Mix formulations for commercial qPCR instruments when running singleplex end-point genotyping assays or multiplex qPCR assays.

*For these instruments, we recommend Standard ROX BHQ Probe Master Mix although the instruments will work with both Low and No ROX mixes. These instruments can read ROX, but the instrument-specific software does not use ROX values for normalisation. Running assays with Standard ROX BHQ Probe Master Mix gives the user the option to export data to alternative software to perform normalisation if required.

Multiplex reactions

If you are using BHQ Probe Master Mix for multiplex reactions, it is important to take your dye selection into account when deciding on the appropriate ROX level for the master mix. The ROX in the BHQ Probe Master Mix will occupy the same channel as CAL Fluor Red 610 and therefore, if this is one of the dyes used in your experiment, the master mix with no ROX will be the most suitable option.

The table below outlines the suggested dye pairings (green for pair 1 and pale orange for pair 2), and consequently the most appropriate version of BHQ Probe Master Mix, for the most commonly used qPCR instruments when performing multiplex reactions. Please note that if the instrument is not listed below, but is listed in our singleplex end-point/multiplex qPCR assays BHQ Probe Master Mix recommendation table (above), then this is because the instrument is not currently capable of reading four or more dyes.

Table 2: Recommended BHQ Probe Master Mix formulations for commercial qPCR instruments when running duplex end-point genotyping assays and multiplex qPCR assays. Recommended dye pairings are highlighted in green for pair 1 and pale orange for pair 2. Second dye pairing is dependent on the filter/colour modules installed.

{{faqs.Name}}