Molecular Trap
Molecular Traps™ with highly activated molecular sieve packets designed to provide and maintain very low water levels in solvents and solutions.
Molecular Traps™ with highly activated molecular sieve packets designed to provide and maintain very low water levels in solvents and solutions.
Phosphoramidite for the incorporation of cholesterol at the 5' end of an oligonucleotide, with a tetraethylene glycol spacer.
CPG used to add the non-fluorescent quencher BHQ-1 dye to the 3' end of an oligonucleotide.
CPG used to add the non-fluorescent quencher BHQ-2 to the 3' end of an oligonucleotide.
CPG column used to add the non-fluorescent quencher BHQ-1 dye to the 3' end of an oligonucleotide.
CPG column used to add the non-fluorescent quencher BHQ-2 to the 3' end of an oligonucleotide.
Phosphoramidite for incorporation of a locked nucleic acid C analogue internally or at the 5' end of an oligonucleotide.
Phosphoramidite used to incorporate a bromo-modified uridine internally or at the 5' end of an oligonucleotide.
CPG column for incorporation of a C16 spacer at the 3' end of an oligonucleotide.
Phosphoramidite used to incorporate a spacer with a photo-cleavable linkage into an oligonucleotide.
Phosphoramidite used to incorporate a 5-nitro-modified indole "universal" base into an oligonucleotide.
CPG column used to incorporate a methyl-dC ROX-phosphate moiety into the 3' end of an oligonucleotide.
Phosphoramidite used for 5'-HEX labelling of an oligonucleotide.
A carboxylic acid used for post-synthetic CAL Fluor Orange 560 labelling of oligonucleotides.
A carboxylic acid ester used for post-synthetic 5'-Quasar 670 labelling of oligonucleotides.
A phosphoramidite used for internally labelling an oligonucleotide with the Quasar 670-dT dye moiety.
O-Ring for waste container carboy cap
Amber glass bottle with 28-400 thread for MerMade synthesizers. Does not include cap.
Amber glass bottle with 28-400 thread for MerMade synthesizers. Does not include cap.
Used to 'cap' unreacted OH groups during oligo synthesis cycle, to prevent unwanted side reactions.
| Europe, Middle East, and Africa | |
|---|---|
| UK | +44 1992 470 757 |
| Germany | +49 30 5304 2200 |
| North America, Latin America | |
| Wisconsin, USA | +1 888 575 9695 |
| Asia Pacific | |
| China | +8621-22509000 |
| Singapore | +65 6734 4800 |
| Europe, Middle East, and Africa | |
|---|---|
| UK | +44 1992 470 757 |
| Germany | +49 30 5304 2200 |
| North America, Latin America | |
| Wisconsin, USA | +1 888 575 9695 |
| Asia Pacific | |
| China | +8621-22509000 |
| Singapore | +65 6734 4800 |